MATERIAL PROPERTY | TEST METHOD | TEST FREQUENCY ft2(m2) |
REQUIRED VALUES |
Bentonite Swell Index1 | ASTM D 5890 | 1 per 50 tonnes | 24 mL/2g min. |
Bentonite Fluid Loss1 | ASTM D 5891 | 1 per 50 tonnes | 18 mL max. |
Bentonite Mass/Area2 | ASTM D 5993 | 40,000 ft2 (4,000 m2) | 0.75 lb/ft2 (3.6 kg/m2) min |
GCL Grab Strength3 | ASTM D 6768 | 200,000 ft2 (20,000 m2) | 50 lbs/in (88 N/cm) MARV |
GCL Peel Strength3 | ASTM D 6496 | 40,000 ft2 (4,000 m2) | 3.5 lbs/in (6.1 N/cm) min |
GCL Index Flux4 | ASTM D 5887 | Weekly | 1 x 10-8 m3/m2/sec max |
GCL Hydraulic Conductivity4 | ASTM D 5887 | Weekly | 5 x 10-9 cm/sec max |
GCL Hydrated Internal Shear Strength5 | ASTM D 5321 ASTM D 6243 |
Periodic |
500 psf (24 kPa) typ @ 200 psf |